Working with Current Setting

The current audit setting determines which events you track for all users on a global basis and whether object auditing is active for all users.

  1. Select 1. Work with Current Setting from the Audit Main menu (STRAUD >1 >1). The Work with Current Setting screen appears.
                          ​ Work with Current Setting​                            
 Use this screen to view or modify the current global audit setting.           ​ 
 The Audit Scheduler may change this setting automatically when active.        ​ 
                                                                                
 Type choices, press Enter.​                                                     
   ​
 Y=Yes​                                                                       
  ​
 Current​ Modified​  Parameter ​ Description​                                     
 Main Audit Control Parameters (QAUDCTL)                                        
     ​
 Y​      ​ Y     ​ *AUDLVL    Activity auditing (as selected below)          ​ 
     ​
 Y​      ​ Y     ​ *OBJAUD    Object access auditing                         ​ 
     ​
 Y​      ​ Y     ​ *NOQTEMP   Do not audit QTEMP objects                     ​ 
 Action Auditing Values (in effect only if *AUDLVL = "Y")                       
     ​ Y​      ​ Y     ​ *CREATE    Create objects                                 ​ 
     ​
 Y​      ​ Y     ​ *DELETE    Delete objects                                 ​ 
     ​
 Y​      ​ Y     ​ *JOBDTA    Start, End, Hold, Release, Change job          ​ 
     ​
 Y​      ​ Y     ​ *NETCMN    Network and communication functions            ​ 
     ​
  ​      ​       ​ *NETBAS    | Network base functions                       ​ 
     ​
  ​      ​       ​ *NETCLU    | Cluster and cluster resource group           ​ 
     ​
  ​      ​       ​ *NETFAIL   | Network failures are audited.                ​ 
     ​
  ​      ​       ​ *NETSCK    | Socket tasks                                 ​ 
                                                                  ​
      More...​ 
 F3=Exit   F4=Prompt   F8=Print  F12=Cancel​                                     
                                                                                
                                                                                
  1. Place a Y or space in the Modified column next to the setting parameters as shown below. You will need to press Page Down to scroll the lower section of the screen to see all of the settings.
  2. Press Enter to return to the menu.